MicroFAST®
Maximum capacity of the purification | Size of the module (L х W х H) |
Weight | |||
Volume of the module | PE of the module | Pound | Kilogram | ||
MicroFAST® 0.5 | 500 GPD (1800 LPD) | 1 to 8 | 59” (150 cm) x 30” (76 cm) x 56” (130 cm) | 165 lbs | 75 kg |
MicroFAST®0.625 | 625 GPD (2300 LPD) | 1 to 10 | 60” (152 cm) x 43” (109 cm) x 55” (130 cm) | 185 lbs | 84 kg |
MicroFAST®0.75 | 750 GPD (2800LPD) | 1 to 11 | 60” (152 cm) x 43” (109 cm) x 55” (130 cm) | 200 lbs | 91 kg |
MicroFAST®0.9 | 900 GPD (3400LPD) | 1 to 14 | 59” (150 cm) x 48” (122 cm) x 57” (145 cm) | 215 lbs | 98 kg |
MicroFAST®1.5 | 1500 GPD (5600LPD) | 6 to 21 | 82” (208 cm) x 55” (140 cm) x 58” (147 cm) | 456 lbs | 207 kg |
MicroFAST®3.0 | 3000 GPD (11350 LPD) | 10 to 42 | 71” (180 cm) x 59” (150 cm) x 81” (206 cm) | 725 lbs | 329 kg |
MicroFAST®4.5 | 45000 GPD (17000 LPD) | 18 to 63 | 145” (368 cm) x 73” (185 cm) x 51” (130 cm) | 1600 lbs | 726 kg |
MicroFAST®9.0 | 9000 GPD (34050 LPD) | 30 to 126 | 145” (368 cm) x 73” (185 cm) x 76” (193 cm) | 2300 lbs | 1044 kg |
Reliable, available… FAST
MicroFAST® systems for purification of water are suitable for dwellings with one family, group of houses or small communities. The MicroFAST modules can be also used for improving other stations, providing the small communities with innovative and available choice as opposed to centralized systems for purification of water.
Established, safe, reliable
The true beauty of those remarkable systems is how good they work.
FAST® is a remarkable simple technology based on nature and simple scientific principles. The FAST (Fixed Activated Sludge Treatment) process use unique hybrid combination of applied and suspended process of growth in aerobic bioreactor. This established IFAS (Integrated Fixed-Film Activated Sludge) combination include the stability of completely submerged, fixed system and the effectiveness of the active sludge purification, making the innovative, original FAST system technologically advanced and incredibly reliable. The FAST process provide ideal environment for fast growth of bacterias, providing a lot of oxygen and food and they are equally distributed to all bacterias at the surface of the equipment.
Reduction of nitrogen
The projects for nitrification and denitrification are much easier with the FAST technology. Many biological, bio-chemical, chemical and physical processes take place simultaneously in the system for purifying waste water FAST. MicroFAST purification systems have proven to reduce nitrogen levels – including nitrates and other nitrogen species – at exceptionally high rates.
How it works?
1. MicroFAST systems for purification of waste water process the polluted water from one-family house, group of houses, small communities or part of the polluted water in other urban stations.
2. The natural separation and settling processes occur prior to entering the treatment module MicroFAST.
3. Mounted at a distance and above the ground compressor, the only moving part of the system, set air (oxygen) in the treatment module to facilitate the circulation of the polluted water through the channels of the installation.
4. FAST fixed system provides high exchange coefficient between the surface and volume to achieve exceptional growth of microbes in small, medium and large use of the system.
5. Clean, odorless, purified water is ready for standard or innovative use.
Technical specifications
Materials of construction: Made with 100% anti-corrosion materials and contain recycled materials.
FAST® Installation: FAST systems are mounted inside tanks above or below ground. The containers can be made of concrete, fiberglass, steel or plastics materials. Please read the product characteristics for tank recommendations. Always check local regulations before installing or altering a wastewater system. Contact us for more information about the container that suits you.
Capacity: FAST are manufactured in several convenient, affordable sizes and configurations. Please contact us for more information about the FAST system that is suitable for you.
Options: Check your local regulations. Extremely high level of purification may allow a reduction of locations for drainage and using the treated water for irrigation or other use.
Power requirements: The electrical components are made according to all world’s electrical characteristics (voltage / phase / frequency).
Maintenance Requirements: Once installed the FAST systems are used with almost no maintenance. The only moving part in the system is the compressor which is mounted on no more than 33 meters from the unit. It is recommended periodic review of electrical components. Residues should be removed when possible.